2023/10/24 更新

写真a

ニシオ フミコ
西尾 文子
NISHIO Fumiko
所属
医歯学域歯学系 医歯学総合研究科 先進治療科学専攻 顎顔面機能再建学講座 助教
職名
助教

経歴

  • 鹿児島大学   医歯学域歯学系 大学院医歯学総合研究科 先進治療科学専攻顎顔面機能再建学講座   助教

    2022年7月 - 現在

 

論文

  • Nishio F, Morita K, Doi K, Kato M, Abekura H, Yamaoka H, Kakimoto N, Tsuga K .  Radiopaque properties of polyetheretherketone crown at laboratory study. .  Journal of oral biosciences   2023年5月

     詳細を見る

    記述言語:英語   出版者・発行元:Journal of Oral Biosciences  

    Objectives: There have been no reports on the radiopaque properties of new polyetheretherketone (PEEK) crowns for locating crowns during accidental ingestion or aspiration and detection of secondary caries, which is essential information for clinical application. This study aimed to investigate whether the radiopaque properties of PEEK crowns could be used to identify the site of accidental ingestion or aspiration and detect secondary caries. Methods: Four types of crowns were fabricated: three non-metal crowns (PEEK, hybrid resin, and zirconia) and one full metal cast crown (gold-silver-palladium alloy). Initially, the images for these crowns were compared using intraoral radiography, chest radiography, cone-beam computed tomography (CBCT), and multi-detector computed tomography (MDCT); computed tomography (CT) values were calculated. Subsequently, the images for the crowns placed on the secondary caries model with two artificial cavities were compared using intraoral radiography. Results: The PEEK crowns displayed the lowest radiopaque properties on radiography and very few artifacts were observed on CBCT and MDCT. On the other hand, the CT values of the PEEK crowns were a little lower than those of the hybrid resin crowns and considerably lower than the zirconia and full metal cast crowns. The cavity could be detected in the PEEK crown-placed secondary caries model through intraoral radiography. Conclusions: This simulated study of radiopaque properties with four types of crowns suggested that a radiographic imaging system can be used to identify the site of accidental ingestion and aspiration of PEEK crowns and to detect secondary caries of the abutment tooth within a PEEK crown.

    DOI: 10.1016/j.job.2023.05.002

    Scopus

    PubMed

  • 伊吹 真知, 杉本 恭子, 村原 貞昭, 西尾 文子, 南 弘之 .  デュアルキュア型レジンセメントに対する初期硬化後の光照射がCAD/CAM用コンポジットレジンの接着強さに及ぼす影響 .  接着歯学41 ( 1 ) 2 - 6   2023年4月

     詳細を見る

    記述言語:日本語   出版者・発行元:(一社)日本接着歯学会  

    本研究の目的は,デュアルキュア型レジンセメントで装着されたCAD/CAM用コンポジットレジンクラウンの外面より行う光照射が,初期接着強さに及ぼす光照射の影響を明らかにすることである.CAD/CAM用コンポジットレジンブロックを厚さ2mmに切断して試験片とし,被着面にリン酸処理およびシラン処理を行った.金銀パラジウム合金で製作した剪断試験用ハンドルをレジンセメントにて接着した.初期硬化後に冠外面より光照射した状況を想定し,接着の5分後に光照射を行った.試験片は90枚準備し,照射なし群,照射3秒群,照射20秒群の3群に分けた.ISO/TR 11405に則って,各群の試験片の半分(n=15)は接着操作の1時間後に剪断接着強さを測定し,各群の残り半分(n=15)は接着操作の24時間後に剪断接着強さを測定した.接着操作の1時間後における照射20秒群の接着強さは,他の2群よりも有意に高かった.接着操作の24時間後の接着強さは,すべての群間で有意差はみられなかった.20秒照射群の1時間後と全群24時間後の間に接着強さの有意差は認めなかった.このことから,CAD/CAMコンポジットレジンクラウンの装着時に十分な時間光を照射することにより,高い初期接着強さが得られることが示された.(著者抄録)

  • Kimura H., Morita K., Nishio F., Abekura H., Tsuga K. .  Clinical report of six-month follow-up after cementing PEEK crown on molars .  Scientific Reports12 ( 1 ) 19070   2022年12月

     詳細を見る

    記述言語:日本語   出版者・発行元:Scientific Reports  

    We conducted a six-month clinical follow-up on computer-aided design/computer-aided manufacturing-fabricated molar polyetheretherketone PEEK crowns to investigate their therapeutic effect. Only the PEEK crowns were examined as our study focused on short-term clinical evaluation of the new PEEK material. Twenty-three cases of PEEK crowns placed on the molars of 20 subjects (7 males and 13 females, mean age: 60.6 ± 14.2 years) were included in the study. The evaluation items were the condition of the crowns at the time of cementation and after six months, patient satisfaction, masticatory ability, and occlusal force. Mann–Whitney U tests with a significance level of 5% were used to examine the difference in glucose concentration by masticatory ability, occlusal pressure, and occlusal force, with and without PEEK crowns. The occlusion, margin fit, and contact of all 23 cases at the time of cementing were good. Six months after cementation, there was no crown desorption, fracture or crack, and prosthodontics was not needed in the 22 cases (one patient dropped out). No wear of the dental antagonist was observed. Patient satisfaction was generally high. There was no significant difference in masticatory ability between the groups with and without PEEK crowns. The subject's occlusal force was within the normal range. PEEK crowns used on molars can replace metal crowns and hold promise for an appropriate and effective treatment.

    DOI: 10.1038/s41598-022-23458-5

    Scopus

    PubMed

  • Kimura Hitomi, Tsuka Hiroki, Morita Koji, Hirata Isao, Nishio Fumiko, Abekura Hitoshi, Doi Kazuya, Tsuga Kazuhiro .  Nd:YVO4レーザーでの溝加工処理により歯科用PEEK材料と接着性レジンセメントの間の接着システム使用によるせん断接着強さは向上する(Nd:YVO4 laser groove treatment can improve the shear bond strength between dental PEEK and adhesive resin cement with an adhesive system) .  Dental Materials Journal41 ( 3 ) 382 - 391   2022年5月

     詳細を見る

    記述言語:英語   出版者・発行元:(一社)日本歯科理工学会  

    歯科用ポリエーテルエーテルケトン(PEEK)材料と接着性レジンセメントの間のせん断接着強さ(SBS)に対する各種表面処理の影響を調べた。PEEK材(Vestakeep DC4450)から円板等の形状に切り出したものを検体とした。サンドブラスト、硫酸エッチング(硫酸群)、レーザー溝加工(LG群)のいずれかの表面処理を行う3群、または無処理の対照群を設定した。それらの表面特性を解析した。その結果、Nd:YVO4レーザーを使用したLG群では検体表面に精密な溝が形成され、熱分解によって炭化している様子が観察された。LG群の表面粗さと水接触角は4群の中で最も高い値となった。次に各群の検体に円柱状の検体を接着してSBS測定などを行った。接着性レジンセメントにはRelyX UltimateまたはスーパーボンドC&Bのいずれかを、接着システムにはVisio.linkを使用した。接着後は24時間水中保管し、一部の検体には1万サイクルの熱サイクルを加え、SBSを測定して破壊様式を調べた。その結果、LG群と硫酸群のSBS値は有意に上昇していることが示された。LG群の検体が示した破壊様式は凝集破壊であった。PEEKと接着性レジンセメントの間のSBSはレーザー溝加工処理によって向上させることが可能であった。

講演・口頭発表等

  • 加藤 真康, 安部倉 仁, 西尾 文子, 木村 仁美, 横井 美有希, 香川 和子, 堂脇 一朗, 森田 晃司, 津賀 一弘 .  歯冠色PEEK材の研磨方法の検討 .  日本補綴歯科学会誌  2022年7月  (公社)日本補綴歯科学会

     詳細を見る

    記述言語:日本語  

  • 横井 美有希, 安部倉 仁, 香川 和子, 西尾 文子, 木村 仁美, 梅原 華子, 沖 佳史, 土井 一矢, 森田 晃司, 津賀 一弘 .  大臼歯PEEKクラウン装着から2年経過した8症例 .  日本補綴歯科学会誌  2022年7月  (公社)日本補綴歯科学会

     詳細を見る

    記述言語:日本語  

  • 伊吹 真知, 西尾 文子, 村原 貞昭, 村口 浩一, 門川 明彦, 嶺崎 良人, 南 弘之 .  光照射がCAD/CAMコンポジットブロックに対する接着強さに及ぼす影響 .  日本補綴歯科学会誌  2022年11月  (公社)日本補綴歯科学会

     詳細を見る

    記述言語:日本語  

  • 西尾 文子, 森田 晃司, 土井 一矢, 平田 伊佐雄, 木村 仁美, 安部倉 仁, 津賀 一弘, 柿本 直也 .  PEEKクラウンのX線不透過性についての基礎実験 .  日本歯科理工学会誌  2021年3月  (一社)日本歯科理工学会

     詳細を見る

    記述言語:日本語